Datasheet
Data Sheet BTS555
Infineon Technologies AG 2 2010-June-01
Pin Symbol Function
1 OUT
Output to the load. The pins
1 and 5 must be shorted with each other
especially in high current applications!
3)
2 IN Input, activates the power switch in case of short to ground
3 V
bb
Positive power supply voltage, the tab is electrically connected to this pin.
In high current applications the tab should be used for the V
bb
connection
instead of this pin
4)
.
4 IS
Diagnostic feedback providing a sense current proportional to the load
current; zero current on failure (see Truth Table on page 7)
5 OUT
Output to the load. The pins
1 and 5 must be shorted with each other
especially in high current applications!
3)
Maximum Ratings at Tj = 25 °C unless otherwise specified
Parameter Symbol Values Unit
Supply voltage (see page 4 and 5) V
bb
40 V
Supply voltage for full short circuit protection,
(E
AS
limitation see diagram on page 10) T
j,start
=-40°C…+150°C:
V
bb
34 V
Load current (short circuit current, see page 5) I
L
self-limited A
Load dump protection V
LoadDump
= U
A
+ V
s
, U
A
= 13.5 V
R
I
5)
= 2 Ω, R
L
= 0.1 Ω, t
d
= 200 ms,
IN, IS = open or grounded
V
Load dump
6
)
80 V
Operating temperature range
Storage temperature range
T
j
T
stg
-40 ...+150
-55 ...+150
°C
Power dissipation (DC), T
C
≤ 25 °C P
tot
360 W
Inductive load switch-off energy dissipation, single pulse
V
bb
= 12V, T
j,start
= 150°C, T
C
= 150°C const.,
I
L
= 20 A, Z
L
= 15 mH, 0 Ω, see diagram on page 10
E
AS
3J
Electrostatic discharge capability (ESD)
Human Body Model acc. MIL-STD883D, method 3015.7 and ESD
assn. std. S5.1-1993, C = 100 pF, R = 1.5 kΩ
V
ESD
4.0 kV
Current through input pin (DC)
Current through current sense status pin (DC)
see internal circuit diagrams on page 8 and 9
I
IN
I
IS
+15 , -250
+15 , -250
mA
3)
Not shorting all outputs will considerably increase the on-state resistance, reduce the peak current capability
and decrease the current sense accuracy
4)
Otherwise add up to 0.5 mΩ (depending on used length of the pin) to the R
ON
if the pin is used instead of the
tab.
5)
R
I
= internal resistance of the load dump test pulse generator.
6)
V
Load dump
is setup without the DUT connected to the generator per ISO 7637-1 and DIN 40839.