Truth Table
( each channel )
IN OUT ST
Normal operation L
H
L
H
H
H
Open load L
H
Z
H
L
19)
H
Overtemperature L
H
L
L
H
L
L = "Low" Level X = don't care Z = high impedance, potential depends on external circuit
H = "High" Level Status signal valid after the time delay shown in the timing diagrams
Parallel switching of channel 1 and 2 is easily possible by connecting the inputs and outputs in parallel (see truth
table). If switching channel 1 to 2 in parallel, the status outputs ST1 and ST2 have to be configured as a 'Wired
OR' function with a single pull-up resistor.