Datasheet

Data Sheet 7 V1.1, 2007-05-29
Smart High-Side Power Switch
BTS5210L
Parameter and Conditions,
each of the four channels
Symbol Values Unit
at Tj = -40...+150°C,
V
bb
= 12 V unless otherwise specified
min typ max
Reverse Battery
Reverse battery voltage
16
)
-
V
bb
-- -- 32 V
Drain-source diode voltage
(V
out
> V
bb
)
I
L
= - 2.0 A,
T
j
= +150°C
-
V
ON
-- 600 -- mV
Diagnostic Characteristics
Open load detection voltage
V
OUT(OL)1
1.7 2.8 4.0 V
Input and Status Feedback
17)
Input resistance
(see circuit page 9)
R
I
2.5 4.0 6.0 k
Input turn-on threshold voltage
V
IN(T+)
-- -- 2.5 V
Input turn-off threshold voltage
V
IN(T-)
1.0 -- -- V
Input threshold hysteresis
V
IN(T)
-- 0.2 -- V
Status change after positive input slope
18)
with open load
t
d(STon)
-- 10 20 s
Status change after positive input slope
18)
with overload
t
d(STon)
30 -- -- s
Status change after negative input slope
with open load
t
d(SToff)
-- -- 500 s
Status change after negative input slope
18)
with overtemperature
t
d(SToff)
-- -- 20 s
Off state input current
V
IN
= 0.4 V:
I
IN(off)
5 -- 20 µA
On state input current
V
IN
= 5 V:
I
IN(on)
10 35 60 µA
Status output (open drain)
Zener limit voltage
I
ST
= +1.6 mA:
ST low voltage
I
ST
= +1.6 mA:
V
ST(high)
V
ST(low)
5.4
--
--
--
--
0.6
V
16)
Requires a 150 resistor in GND connection. The reverse load current through the intrinsic drain-source
diode has to be limited by the connected load. Power dissipation is higher compared to normal operating
conditions due to the voltage drop across the drain-source diode. The temperature protection is not active
during reverse current operation! Input and Status currents have to be limited (see max. ratings page 4 and
circuit page 9).
17)
If ground resistors R
GND
are used, add the voltage drop across these resistors.
18)
not subject to protection test, specified by design