Datasheet
Data Sheet 11 Rev. 2.1, 2011-09-01
PROFET™+ 12V
BTS5045-2EKA
General Product Characteristics
4.2 Functional Range
Table 3 Functional Range T
J
= -40°C to +150°C; (unless otherwise specified)
Parameter Symbol Values Unit Note /
Test Condition
Number
Min. Typ. Max.
Nominal operating voltage
V
NOM
8 13.5 18 V – P_4.2.1
Extended operating voltage
V
S(OP)
5–28 V
2)
V
IN
= 4.5 V
R
L
= 6 Ω
V
DS
< 0.5 V
See Figure 15
P_4.2.2
Minimum functional supply
voltage
V
S(OP)_MIN
3.8 4.3 5 V
1)
V
IN
= 4.5 V
R
L
= 6 Ω
From I
OUT
= 0 A
to
V
DS
< 0.5 V;
See Figure 15
See Figure 29
P_4.2.3
Undervoltage shutdown
V
S(UV)
3 3.5 4.1 V
1)
V
IN
= 4.5 V
V
DEN
= 0 V
R
L
= 6 Ω
From V
DS
< 1 V;
to I
OUT
= 0 A
See Figure 15
See Figure 30
P_4.2.4
Undervoltage shutdown
hysteresis
V
S(UV)_HYS
– 850 – mV
2)
– P_4.2.13
Operating current
One channel active
I
GND_1
–3.56mAV
IN
= 5.5 V
V
DEN
= 5.5 V
Device in R
DS(ON)
V
S
= 18 V
See Figure 31
P_4.2.5
Operating current
All channels active
I
GND_2
–58mAV
IN
= 5.5 V
V
DEN
= 5.5 V
Device in R
DS(ON)
V
S
= 18 V
See Figure 32
P_4.2.6
Standby current for whole
device with load (ambiente)
I
S(OFF)
–0.10.5μA
1)
V
S
= 18 V
V
OUT
= 0 V
V
IN
floating
V
DEN
floating
T
J
≤ 85 °C
See Figure 33
P_4.2.7