Datasheet
Smart High-Side Power Switch
BTS5016SDA
Protection Functions
Datasheet 20 Rev. 1.1, 2008-11-04
Overvoltage
6.7.13 Overvoltage protection
V
Z
V I
bb
= 15 mA
Input pin
V
Z,IN
63 - - V
Sense pin
V
Z,IS
63 - - V
1) Not subject to production test, specified by design
2) Short circuit current limit for max. duration of
t
d(SC1)
, prior to shutdown, see also Figure 12.
3) min. value valid only if input “off-signal” time exceeds 30 µs
V
bb
= 12 V, T
j
= -40 ... 150 °C (unless otherwise specified) Typical values are given at V
bb
= 12 V, T
j
= 25 °C
Pos. Parameter Symbol Limit Values Unit Conditions
Min. Typ. Max.