Datasheet

Smart High-Side Power Switch
BTS50080-1TEA
Protection Functions
Datasheet 18 Rev. 1.0, 2008-08-28
6.4 Overvoltage Protection
Beside the output clamp for the power stage as described in Section 5.3 there is a clamp mechanism
implemented for all logic pins. See Figure 15 for details.
Figure 15 Overvoltage Protection
6.5 Loss of Ground Protection
In case of complete loss of the device ground connections the BTS50080-1TEA securely changes to or remains
in off state.
6.6 Loss of V
bb
Protection
In case of complete loss of V
bb
the BTS50080-1TEA remains in off state.
In case of loss of V
bb
connection with charged inductive loads a current path with load current capability has to be
provided, to demagnetize the charged inductances. It is recommended to use a diode, a Z-diode, or a varistor
(
V
ZL
+V
D
< 30 V or V
Zb
+V
D
< 16 V if R
IN
= 0). For higher clamp voltages currents through IN and IS have to be limited
to -140 mA. Please refer to Figure 16 for details.
Figure 16 Loss of V
bb
OverVolt age .emf
IN
R
bb
V
bb
Logic
V
Z,IS
V
Z,IN
IS OUT
IN
R
bb
V
bb
Logic
IS
V
bb
R
IS
R
IN
V
D
V
ZL
inductive
LOAD
Vbb_disconnect_A.emf
IN
V
bb
Lo g ic
IS
V
bb
R
IS
R
IN
inductive
LOAD
V
D
V
Zb
Vbb_disconnect _B. emf
R
bb