Datasheet

Smart High-Side Power Switch
BTS50080-1TEA
Power Stages
Datasheet 10 Rev. 1.0, 2008-08-28
Figure 6 Typical On-State Resistance
Figure 7 Typical Output Voltage Drop Limitation
5.3 Output Inductive Clamp
When switching off inductive loads, the output voltage V
OUT
drops below ground potential due to the involved
inductance ( -d
i
L
/dt =-v
L
/L ; -V
OUT
-V
L
).


  




ȍ



    
ȍ









 





V
bb
= 12 V
T
j
= 25°C