Datasheet

Data Sheet BTS50055-1TMB
Infineon Technologies AG Page 5 2010-April-27
Parameter and Conditions Symbol Values Unit
at Tj = -40 ... +150 °C, V
bb
= 12 V unless otherwise specified
min typ max
Protection Functions
16
)
Short circuit current limit (Tab to pins 1, 2, 6, 7)
V
ON
= 12 V, time until shutdown max. 350 µs T
c
=-40°C:
T
c
=25°C:
T
c
=+150°C:
I
L(SC)
I
L(SC)
I
L(SC)
--
--
65
110
130
115
--
180
--
A
Short circuit shutdown delay after input current
positive slope, V
ON
> V
ON(SC)
min. value valid only if input "off-signal" time exceeds 30 µs
t
d(SC)
80
-- 350 µs
Output clamp
17
)
I
L
= 40 mA:
(inductive load switch off)
see diagram Ind. and overvolt. output clamp page 8
-V
OUT(CL)
14
16.5
20 V
Output clamp (inductive load switch off)
at V
OUT
= V
bb
- V
ON(CL)
(e.g. over voltage)
I
L
= 40 mA
V
ON(CL)
39
42 47 V
Short circuit shutdown detection voltage
(pin 4 to pins 1,2,6,7)
V
ON(SC)
--
6 -- V
Thermal overload trip temperature T
jt
150 -- -- °C
Thermal hysteresis
T
jt
-- 10 -- K
Reverse Battery
Reverse battery voltage
18
)
-V
bb
-- -- 16 V
On-state resistance (Pins 1 ,2 ,6 ,7 to pin 4) T
j
= 25 °C:
V
bb
= -12V, V
IN
= 0, I
L
= - 20 A, R
IS
= 1 k T
j
= 150 °C:
R
ON(rev)
--
5.4
8.9
7.0
12.3
m
Integrated resistor in V
bb
line R
bb
-- 120 --
16
) Integrated protection functions are designed to prevent IC destruction under fault conditions described in the
data sheet. Fault conditions are considered as “outside” normal operating range. Protection functions are not
designed for continuous repetitive operation.
17
)
This output clamp can be "switched off" by using an additional diode at the IS-Pin (see page 8). If the diode
is used, V
OUT
is clamped to V
bb
- V
ON(CL)
at inductive load switch off.
18
)
The reverse load current through the intrinsic drain-source diode has to be limited by the connected load (as
it is done with all polarity symmetric loads). Note that under off-conditions (I
IN
= I
IS
= 0) the power transistor
is not activated. This results in raised power dissipation due to the higher voltage drop across the intrinsic
drain-source diode. The temperature protection is not active during reverse current operation! Increasing
reverse battery voltage capability is simply possible as described on page 9.