Datasheet
PROFET
®
BTS 432 E2
Parameter and Conditions Symbol Values Unit
at Tj = 25 °C, V
bb
= 12 V unless otherwise specified
min typ max
Data Sheet 5 2010-Jan-26
Input and Status Feedback
12)
Input turn-on threshold voltage
T
j
=-40..+150°C:
V
IN(T+)
1.5 -- 2.4 V
Input turn-off threshold voltage
T
j
=-40..+150°C:
V
IN(T-)
1.0 -- -- V
Input threshold hysteresis ∆ V
IN(T)
-- 0.5 -- V
Off state input current (pin 2) V
IN
= 0.4 V: I
IN(off)
1 -- 30 µA
On state input current (pin 2) V
IN
= 3.5 V: I
IN(on)
10 25 50 µA
Status invalid after positive input slope
(short circuit) T
j
=-40 ... +150°C:
t
d(ST SC)
80 200 400 µs
Status invalid after positive input slope
(open load) T
j
=-40 ... +150°C:
t
d(ST)
350 -- 1600 µs
Status output (open drain)
Zener limit voltage T
j
=-40...+150°C, I
ST
= +1.6 mA:
ST low voltage T
j
=-40...+150°C, I
ST
= +1.6 mA:
V
ST(high)
V
ST(low)
5.4
--
6.1
--
--
0.4
V
12)
If a ground resistor R