Datasheet

BTS4300SGA
Power Stage
Data Sheet 12 Rev. 1.0, 2008-03-18
Following equation simplifies under the assumption of
R
L
= 0.
The energy, which is converted into heat, is limited by the thermal design of the component.
5.4 Electrical Characteristics Power Stage
Electrical Characteristics: Power stage
V
S
= 13.5V, T
j
= -40 °C to +150 °C,(unless otherwise specified). Typical values are given at T
j
= 25°C
Pos. Parameter Symbol Limit Values Unit Conditions
Min. Typ. Max.
5.4.1 ON-state resistance per channel
R
DS(ON)
–300–m T
j
= 25°C,
1)
I
L
= 0.3A,
V
BB
= 9...40V
V
IN
= 5V,
See Figure 4
1) Not subject to production test, specified by design
–480600 T
j
=150°C
5.4.2 Nominal load current
I
L(nom)
0.4––AT
A
=85°C
1)
,
T
j
<150°C
5.4.3 Drain to Source Clamping Voltage
V
DS(AZ)
= V
S
-V
OUT
V
DS(AZ)
41 47 V I
DS
= 4mA
2)
2) Voltage is measured by forcing I
DS.
5.4.4 Output leakage current
I
L(OFF)
––12µAV
IN
=0V,
V
OUT
= 0V
5.4.5 Slew rate ON
10% to 30%
V
OUT
dV/dt
ON
–- –- 2 V/µs R
L
=47Ω,
V
s
=13.5V,
See Figure 5
5.4.6 Slew rate OFF
70% to 40%
V
OUT
-dV/dt
OFF
––2V/µs
5.4.7 Turn-ON time to 90%
V
OUT
Includes propagation delay
t
ON
––140µs
5.4.8 Turn-OFF time to 10%
V
OUT
Includes propagation delay
t
OFF
––170µs
E
1
2
-- -
LI
2
× 1
V
S
V
S
V
DS
AZ )()
-------------------------------------------


×=