Datasheet
Datasheet 13 Rev. 1.1, 2008-02-28
Smart Low Side Power Switch
HITFET - BTS3160D
Supply and Input Stage
5.3 Electrical Characteristics Supply and Input Stages
V
S
= 6 V to 30 V, T
j
= -40 °C to +150 °C
All voltages with respect to ground, positive current flowing into pin (unless otherwise specified)
Pos. Parameter Symbol Limit Values Unit Conditions
Min. Typ. Max.
UV-switch-on voltage V
SUVON
– – 5.5 V V
S
= 5.5 V
UV-switch-off voltage V
SUVOFF
4.0 – – V V
S
= 4.0 V
UV-switch-off hysteresis V
SUVHY
– 0.2 – V V
SUVON
- V
SUVOFF
Low level voltage V
INL
– – 0.8 V V
S
= 6 V;
no fault condition
High level voltage V
INH
2.0 – – V V
S
= 6 V;
no fault condition
Input pull down current I
IN
20 50 100 µA V
IN
= 5.3 V;
no fault condition
I
IN-Fault
1 2 3 mA V
IN
= 5.3 V;
all fault conditions
Input Fault ON threshold I
Fault_ONth
600 uA
1) not subject to production test
1)
Under Voltage Lockout
5.3.1
5.3.2
5.3.3
Digital Input / Fault Feedback
5.3.4
5.3.5
5.3.6
5.3.7