Datasheet

Data Sheet 16 Rev. 2.0, 2010-05-28
High Current H-Bridge
BTM7752G
Block Description and Characteristics
6.3.5 Short Circuit Protection
The device provides embedded protection functions against
output short circuit to ground
output short circuit to supply voltage
short circuit of load
The short circuit protection is realized by the previously described current limitation in combination with the over-
temperature shut down (see
Chapter 6.3.3) of the device.
6.3.6
Pos. Parameter Symbol Limit Values Unit Test Conditions
Min. Typ. Max.
Over Voltage Lock Out
Switch-ON voltage V
OV(ON)
27.8 V V
s
decreasing
Switch-OFF voltage V
OV(OFF)
28 30 V V
s
increasing
ON/OFF hysteresis V
OV(HY)
0.2 V
1) Not subject to production test, specified by design.
1)
Under Voltage Shut Down
Switch-ON voltage V
UV(ON)
5.5 V V
S
increasing
Switch-OFF voltage V
UV(OFF)
4.0 5.4 V V
S
decreasing
ON/OFF hysteresis V
UV(HY)
0.2 V
1)
Thermal Shut Down
Thermal shut down junction
temperature
T
jSD
155 175 200 °C
1)
; V
S
18 V
Thermal switch on junction
temperature
T
jSO
153 190 °C
1)
Thermal hysteresis ΔT 7 °C
1)
Reset pulse at INH and IN pin
(INH, IN1 and IN2 low)
t
reset
8 µs
1)
Current Limitation
Current limitation detection
level high side
I
CLH0
8 12 16 A V
S
= 13.5 V
Current limitation detection
level low side
I
CLL0
8 12 16 A V
S
= 13.5 V
Shut off time for HS and LS t
CLS
50 100 200 µs V
S
= 13.5 V, T
j
= 25 °C
Electrical Characteristics - Protection Functions
V
S
= 8 V to 18 V, T
j
= -40 °C to +150 °C, VS pins shorted, all voltages with respect to ground, positive current
flowing into pin (unless otherwise specified)
6.3.1
6.3.2
6.3.3
6.3.4
6.3.5
6.3.6
6.3.7
6.3.8
6.3.9
6.3.10
6.3.11
6.3.12
6.3.13