Data Sheet

2004-01-27
Page 14
BSP 752 R
Maximum allowable load inductance
for a single switch off
L = f(I
L
); T
jstart
=150°C, R
L
=0
0 0.25 0.5 0.75 1
A
1.5
I
L
0
200
400
600
800
1000
1200
1400
1600
mH
2000
L
42V
13,5V
Typ. status delay time
t
d(ST)
= f(V
bb
); T
j
= 25°C
0 10 20 30
V
50
V
bb
0
25
50
75
100
125
150
175
200
225
250
µs
300
t
d(ST+/-)
td(ST+)
td(ST-)
Maximum allowable inductive switch-off
energy, single pulse
E
AS
= f(I
L
); T
jstart
= 150°C, V
bb
= 13,5V
0 0.25 0.5 0.75 1
A
1.5
I
L
0
200
400
600
800
1000
1200
1400
mJ
1800
E
AS
Typ. internal output pull down
R
O
= f(V
bb
)
0 10 20 30
V
50
V
bb
0
100
200
300
400
500
600
k
800
R
O
-40°C
25°C
150°C