Data Sheet
2004-01-27
Page 14
BSP 752 R
Maximum allowable load inductance 
for a single switch off
L = f(I
L
); T
jstart
=150°C, R
L
=0Ω
0 0.25 0.5 0.75 1
A
1.5
I
L
0 
200 
400 
600 
800 
1000 
1200 
1400 
1600 
mH
2000 
L
42V
13,5V
Typ. status delay time
t
d(ST)
 = f(V
bb
); T
j
 = 25°C
0 10 20 30
V
50
V
bb
0 
25 
50 
75 
100 
125 
150 
175 
200 
225 
250 
µs
300 
t
d(ST+/-)
td(ST+)
td(ST-)
Maximum allowable inductive switch-off
energy, single pulse
E
AS
 = f(I
L
); T
jstart
 = 150°C, V
bb
 = 13,5V
0 0.25 0.5 0.75 1
A
1.5
I
L
0 
200 
400 
600 
800 
1000 
1200 
1400 
mJ
1800 
E
AS
Typ. internal output pull down
R
O
 = f(V
bb
)
0 10 20 30
V
50
V
bb
0 
100 
200 
300 
400 
500 
600 
kΩ
800 
R
O
-40°C
25°C
150°C