Datasheet
AUIPS6011(S)(R)
www.irf.com
4
Static Electrical Characteristics
Tj=-40°C..150°C, Vcc=6..28V (unless otherwise specified), typical values are given for Vcc=14V and Tj=25°C
Symbol
Parameter
Min.
Typ.
Max.
Units
Test Conditions
Rds(on)
ON state resistance Tj=25°C
11
14
m
Vin=5V, Iout=20A
ON state resistance Tj=150°C
19.5
25
Vin=5V, Iout=20A
ON state resistance Tj=25°C, Vcc=6V
12
17
Vin=5V, Iout=20A
ON state resistance during reverse battery
Tj=25°C
15
20
Vcc-Gnd=-14V
Vcc op.
Operating voltage range with short circuit
protection
6
24
V
V clamp 1
Vcc to Out clamp voltage 1
36.5
39
43
Iout=50mA
V clamp 2
Vcc to Out clamp voltage 2
40
Iout=16A (see Fig. 1)
Icc Off
Supply current when Off and Vout
connected to ground with R<4Ω
4
9
µA
Vin=0V, Vout=0V,
Tj=25°C, Vcc=14V
Icc On
Supply current when On
2.2
5
mA
Vin=5V, Vcc=14V
Vih
Input high threshold voltage
2.5
3
V
Vil
Input low threshold voltage
1.5
2
In hyst.
Input hysteresis
0.2
0.5
1
Iin On
Input current when device is On
40
100
µA
Vin=5V
Idg
Dg leakage current
0.1
10
Vdg=5V
Vdg
Low level DG voltage
0.25
0.4
V
Idg=1.6mA
Switching Electrical Characteristics
Vcc=14V, Resistive load=6, Vin=5V, Tj=-40°C..150°C, typical values are given for Tj=25°C
Symbol
Parameter
Min.
Typ.
Max.
Units
Test Conditions
Tdon
Turn-on delay time
30
80
µs
see Fig. 3
Tr1
Rise time to Vout=Vcc-5V
25
80
Tr2
Rise time to Vout=0.9 x Vcc
Tj=-40°C..25°C
80
300
Tj=25°C..150°C
40
100
dV/dt (On)
Turn On dV/dt
0.3
V/µs
EOn
Turn On energy
4
mJ
Tdoff
Turn-off delay time
70
150
µs
Tf
Fall time to Vout=0.1 x Vcc
30
80
dV/dt (Off)
Turn Off dV/dt
0.7
V/µs
EOff
Turn Off energy
1.5
mJ