Product Info

Table Of Contents
Infinet Wireless: Technical Documentation – InfiMAN Evolution
Operation & Administration – 80
7.2.4 Extended Interface Statistics
The "Extended Interface Statistics" tools gather complete information and enhanced statistics for each interface of
the unit. Each interface type has its own set of available tools applicable to it.
In order to access the "Extended Interface Statistics" tools, click on the row of each interface within the "Interface
Statistics" section:
29 Figure - Extended Interface Statistics
7.2.4.1 General Statistics
The "General Statistics" tool displays the information about the interface such as theinterface mode, current status,
Rx and Tx statistics,etc. The actual statistics details depend on the interface type.
For Ethernet interfaces information about current status, operational mode and load statistics is available.
30 Figure - General Statistics Ethernet
Rx and Tx statistics parameters:
Parameter Description
Receive statistics
Packets The total number of received packets
Bytes The sum of lengths of all good Ethernet frames received
Load (kbps) The link load, Kbit/s
Load (pps) The link load, packets per second
Frame size (bytes) The frame size in bytes
CRC errors Total frames received with a CRC error