Infinet Wireless: Technical Documentation – InfiMAN Evolution
Installation – 65
15 Figure - AUX-ODU-LPU-G Assembly Scheme
6.4.3.1 AUX-ODU-LPU-GMounting
AUX-ODU-LPU-Gcan be installed on a pole, using hose clamps. Attach the grounding cable (min cross-section 2.5
mm
2
) to the case, using grounding bolt.
16 Figure - AUX-ODU-LPU-G Mounting
During AUX-ODU-LPU-G mounting it is necessary to provide a small loop of the FTP Cat5e cable that should be
below the cable gland. These ensure that water is not constantly channeled towards the connectors. It will also
serve as a cable compensator for the cable linear expansion as the temperature difference result.
CAUTION
Please note grounding cables should not be connected to the mast. All devices must use separate
grounding cable that should be connected to the grounding circuit. The best scenario is when grounding
cables are lined parallel to the Ethernet cable.