Product Info

Table Of Contents
Infinet Wireless: Technical Documentation – InfiMAN Evolution
Installation – 59
1.
2.
3.
4.
5.
6.
7.
8.
Install ODU connector facing down using the mounting kit.Do not tighten the fasteners to the end until the
alignment is completed.
Connect the Cat5e FTP cable with the cable gland to ODU.
Perform ODU grounding.
Lay the Cat5e FTP cable from ODU to the power supply.
Connect the Cat5e FTP cable with a shielded connector covered by a cap to the "OUT" port of the power
supply, having previously touched the power supply connector case with FTP cable connector case.
Perform the power supplygrounding.
Connect the laptop using Cat5e FTP cableto the power supply "IN" port.
Connect the power cord to the power supply and then to the power circuit.
Make sure a small loop (at least 10 cable diameters) is provided before the Cat5e FTP cable enter into the building.
Any external antenna of the same type and with a maximum gain notgreaterthan those listed below can
be used with the InfiMAN Evolution / InfiLINK Evolution E5-STE, E6-STEinthecountriesabidingby theFCC
rules.
Directivity Type Manufacturer Reference Stated Gain
Sectorized Flat-panel, dual
orthogonal polarization
array
MARS Antennas &RF
Systems Ltd.
MA-WC56-DP17 18 dBi
If other antenna types thanabovewithGain +18dBi or LESS are used with this device these antenna types
must be approved by FCC with C2PC application by device manufacturer.
External antenna must be professionally installed pursuant to the section 15.203 of the FCC Rules.
CAUTION
In order to prevent device damage make sure that antenna is connected tobothN-type connectors
withserviceable RF cables before switching on.
CAUTION
Thepower supply must not operate near a direct heat source, near water or in an environment with
high humidity.The cables must be connected in such a way to prevent water flow to the power
supply connectors.
CAUTION
Use mains supply cords that adhere to safety regulations of the country where the equipment is
getting deployed.