Product Info
Table Of Contents
- About This Manual
- Important Notice
- Introduction
- Document structure
- Document marks
- Key Features
- Hardware Platform
- Power supply
- Lightning protection unit
- Synchronization unit
- // 0) { /* For each inline-commented element clear data-ref and class */ for (var i=0; i < commentedElements.length; i++) { commentedElements[i].dataset.ref= ""; commentedElements[i].className = ""; } } /* Else do nothing */ } }); //]> AUX-ODU-SYNC Mounting
- AUX-ODU-SYNC Cable gland Assembling
- AUX-ODU-SYNC Connection to ODU
- Packing List
- Planning considerations
- Link Pre-configuration in the lab
- Installation
- Operation & Administration
- Troubleshooting
- Glossary
Infinet Wireless: Technical Documentation – InfiMAN Evolution
Installation – 56
1.
2.
3.
4.
•
•
•
5.
•
•
•
•
•
•
6.2 Cable Gland Assembly
6.2.1 Cable Gland Assembly for RJ-45 connector
Required components are listed below.
Unshielded RJ-45 connector.
Shielded RJ-45 connector.
FTP Cat5e cable.
Cable gland:
Cable gland nut.
Split sealing grommet (with inner diameter 7 mm).
Cable gland threaded coupling.
Crimping tool for RJ-45 connector.
6.2.1.1 Assemble procedure
In order to ensure that the device case remains sealed under any environmental conditions follow the assemble
procedure:
Step 1:Crimp the standard RJ-45 connector onto the cable using crimping tool.Pin-out scheme: T568B
wiring standard.
Step 2: Assemblecable gland nut, the split sealing grommet and the cable gland threaded coupling onto the
pre-terminated cableas shown on the figure below.
Step 3: Insert the split sealing grommet into the cable gland threaded coupling.
Step 4: Insert the RJ-45 connector into the device socket until you hear a click.
Step 5: Screw thecable gland threaded coupling into the port and tighten it.Do not apply excessive force.
Step 6:Tighten the cable gland nut (4). Do not apply excessive force.
NOTE
The outside diameter value of the FTP Cat5e cable should not exceed 7 mm.
NOTE
Cable gland can be assembled on pre-crimped cable.
NOTE
Do not use the shielded RJ-45 connector on this end of the cable as it should be attached on the power
supply unit end.
CAUTION
Make sure that the RJ-45 connector is well-crimped. A loose connector can damage the device. Please note
that such damage is not covered by the warranty.