Infinet Wireless: Technical Documentation – InfiMAN Evolution
Link Pre-configuration in the lab – 50
•
•
•
•
•
The rest of parameters remain with the default values.
At the unit named Slave at step #3 above,go to the Basic Settings section, then to Link Settings and set this unit
with:
Type:Slave.
Tx Power: e.g., 0 dBm (set the minimum value in the range, as currently,we are in the lab, and we don't
need high output power anymore).
Node Name: e.g., Slave (it is the same as the value set at Device Name if this was saved before).
Channel Width: e.g., 80 MHz.
Frequency: e.g., 6020 MHz.
The rest of parameters remain with the default values.