Product Info
Table Of Contents
- About This Manual
- Important Notice
- Introduction
- Document structure
- Document marks
- Key Features
- Hardware Platform
- Power supply
- Lightning protection unit
- Synchronization unit
- // 0) { /* For each inline-commented element clear data-ref and class */ for (var i=0; i < commentedElements.length; i++) { commentedElements[i].dataset.ref= ""; commentedElements[i].className = ""; } } /* Else do nothing */ } }); //]> AUX-ODU-SYNC Mounting
- AUX-ODU-SYNC Cable gland Assembling
- AUX-ODU-SYNC Connection to ODU
- Packing List
- Planning considerations
- Link Pre-configuration in the lab
- Installation
- Operation & Administration
- Troubleshooting
- Glossary
Infinet Wireless: Technical Documentation – InfiMAN Evolution
Introduction – 24
•
•
IDU-LA-G(V.01)is an indoor DC/DC injector. It greatly reduces complexity of the deployment in the cases where DC
source is available thus reducing both capital expenditures and total cost of ownership.
IDU-LA-G(V.01) may be used for the following purposes:
To serve as a line protection unit for indoor network equipment connected to the second Ethernet port on
ODU.
To connect third-party DC power sources to ODU (for example, to power the unit from solar power or wind
power sources).
Technical parameters
Parameter Description
Compatible models InfiLINK XG, InfiLINK XG 1000, InfiLINK 2x2, InfiMAN 2x2,
Quanta 5, Quanta 6, Quanta 70, InfiLINK Evolution, InfiMAN
Evolution
Output Voltage The same as input
Supported Ethernet Modes 10/100/1000 Mbps (Gigabit Ethernet pass-through)
Pin assignment and polarity 1/2 (+), 3/6 (-), 4/5 (+), 7/8 (-)
DC Range Acceptable input DC range depends on the specific ODU
model:
• InfiLINK XG, InfiLINK XG 1000, InfiLINK 2x2 PRO, InfiMAN 2x2
BS, Quanta 70, Quanta 5, Quanta 6, InfiLINK Evolution, InfiMAN
Evolution models: ±43... ±56 VDC
• InfiLINK 2x2 Lite, InfiMAN 2x2 STE models: +9... +56 VDC
(positive voltage only)
Size and Weight 115×65×40 mm, 0.15 kg
Operating temperature range from 0°С to +40°С
Connectors description
CAUTION
Exposing unit to the unsupported voltage will result in irreparable damage to the unit! Always observe
power requirements!