Infinet Wireless: Technical Documentation – InfiMAN Evolution
Introduction – 21
•
•
•
•
•
•
•
•
•
Parameter Description
Input Power
Requirements
AC Input Voltage: 100 ... 240 VAC
AC Input Current: 0.75 A
AC Frequency: 50 to 60 Hz
Consumption 28 W
Operating
temperature
range
-10 °С ... +40 °С
Operating
humidity
Maximum 95 %, Non-condensing
Storage
temperature
-40°С... +70°С
Output Power
Voltage
48 VDC, 0.5 A
Ethernet
Connectors Pin-
out
LAN Pin 1 2 3 4 5 6 7 8
Descrip
tion
A+ A- B+ C+ C- B- D+ D-
POE Pin 1 2 3 4 5 6 7 8
Descrip
tion
A+ A- B+ +VDC /
C+
+VDC /
C-
B- -VDC /
D+
-VDC /
D-
Safety UL cUL, CE, GS, CCC, FCC, S-MARK, PSE, C-tick, KC(48V0.5A) BIS(24V1A)
1 Table - IDU-CPE-G(24W) Specification
3.5.2 Indoor AC/DC injector with integrated lightning protection IDU-BS-G(60W)