Operation & Administration – 147
82 Figure - Spectrum analyzer
The following parameters are available in order to operate the Spectrum Analyzer:
Parameter Description
Interface rf6.0 radio interface is the only option available, but it is showed for
the backward compatibility with the dual radio legacy products
Start Frequency Set the first frequency for scanning (in MHz)
Stop Frequency Set the last frequency for scanning (in MHz)
Band Set the bandwidth (in MHz)
Step Set the scanning frequency step (in MHz)
It is recommended to set 1 MHz “step” value to get more precise
scanning results
Channel Mask Select which antenna to be used for scanning the radio
environment
Auto” parameter is set by default. In this case scanning is
perfomed by both antennas
"1" - scanning is perfomed by antenna "1"
"2" - scanning is perfomed by antenna "2"
Parameter "3" means scanning is perfomed by both antennas
Scan Duration Set the time period for the scanning process (in seconds)
After the end of this time period, scanning is stopped and the radio
interface will be back to its normal mode operation
Enable Grid Mark/unmark the corresponding checkbox to display/hide the grid
lines and highlight the special frequency channel on the scan
output
The highlighted frequency channel can be used to mark the
channel which the device is currently working on or which it plans
to use
Grid Width Set the bandwidth value for the highlighted frequency channel (in
MHz)