Infinet Wireless: Technical Documentation – InfiMAN Evolution
Troubleshooting – 157
•
•
1.
2.
3.
4.
the switch would prevent your PC Ethernet interface from flapping up and down. Using Cisco Catalyst
switches for unit recovery is not recommended due to a known issue port mode negotiation delay.
IP address should be configured on the PC for the ERConsole utility work.
109 Figure - The recommended connection scheme
Set default gateway address to the same network interface configuration connected to Infinet Wireless unit
or to switch connected with Infinet Wireless unit. Turn off all the network interfaces (except Ethernet
interface connected to Infinet Wireless unit).
Step-by-step instruction to obtain or add additional IP-address via ERConsole operation
Run the ERConsole.jar application downloaded from our FTP.
Connect a network Ethernet cables between the Infinet Wireless unit,unmanaged switch and your PC,as
shown in the figure above.
Turn offthe InfiNet Wireless unit by removing ethernet cable from power supply unit and thenturn it onin a
few seconds.
Waitfor30 seconds and the ERConsole screen should receive update from the unitas shown in the figure
below. The Serial number, number of device reset cycles ("Sequence" field),IP-address, network mask and
MAC-adress will be displayed on the screen.
110 Figure - ERConsole information
NOTE
ERConsole and InfiNet Wireless units exchange information only during the bootup process, therefore
each time you need to read the units IP-address, to add a new IP-address or to restore to the default
configuration, the InfiNet Wireless unit should be rebooted.