Install Instructions
Table Of Contents
- About This Manual
- Important Notice
- Introduction
- Document structure
- Document marks
- Key Features
- Hardware Platform
- Power supply
- Lightning protection unit
- Synchronization unit
- // 0) { /* For each inline-commented element clear data-ref and class */ for (var i=0; i < commentedElements.length; i++) { commentedElements[i].dataset.ref= ""; commentedElements[i].className = ""; } } /* Else do nothing */ } }); //]> AUX-ODU-SYNC Mounting
- AUX-ODU-SYNC Cable gland Assembling
- AUX-ODU-SYNC Connection to ODU
- Packing List
- Planning considerations
- Link Pre-configuration in the lab
- Installation
- Operation & Administration
- Troubleshooting
- Glossary
Infinet Wireless: Technical Documentation – InfiMAN Evolution
59 https://wiki.infinetwireless.com/display/DR/TDMA+and+Polling%3A+Application+features
60 https://wiki.infinetwireless.com/pages/viewpage.action?pageId=42274923
61 https://wiki.infinetwireless.com/pages/viewpage.action?pageId=43827064
Troubleshooting – 156
•
•
•
•
8.5.1 Autobitrate and ATPC
To keep a balance between the wireless link's performance and the retries number, we recommend to alwaysset
the "Bitrate" parameter to "Auto" mode.Also enable the automatic transmit power control (ATPC) in order to
increase the operational life of the devices.
8.5.2 Frame size
Make sure that the selected frame size ensures the best performance for your wireless system.A short frame will
transmit less payload than a long one, however it ensures a smaller delay.A detailed description of the frame sizes
in the TDMA technology is available in the "TDMA and Polling: Application features
59
" article.
8.5.3 Packet retries management
The "Turbo" mode is available in the TDMA software version, which allow to increase the wireless link throughput in
case that the degradation is caused by a large number of errors in the radio.
Detailed information about the radio parameter configuration via the web interface is available in the "Link
Settings (see page 91)"articleor via CLI in the articles: "mint command (TDMA version)
60
"and "rfconfig command
(TDMA version)
61
".
8.6 Emergence Repair Console
If the management of the unit is completely lost (of the local and/or the remote one), the ERConsole recovery
procedure should be used. ERConsole is a software application created to recover or add a new IP address to the
InfiNet Wireless units. Additionally, the ERConsole can be used to reset the Infinet Wireless units to the factory
default configuration.
8.6.1 ERConsole recovery procedure
Required software
Java Runtime Environment should be installed. Please download it if it is not installed:http://
www.java.com/en/download/
Download ERConsole from our ftp site:ftp://ftp.infinet.ru/pub/Utils/EmergenceRepairConsole/
ERConsole.zip
Network Requirements
Turn off any anti-virus or firewall running on your computer. If no device can be discovered by ERConsole,
turn on the firewall, and add an UDP connection port 10009 as an exception.
Use a simple unmanaged switch as intermediary device between your PC and theInfinetunit. It is essential
to reboot the InfiNet unit each time in order to activate the Emergency Repair Protocol on the unit, therefore










