Infinet Wireless: Technical Documentation – InfiMAN Evolution
50 https://wiki.infinetwireless.com/pages/viewpage.action?pageId=43827064
Troubleshooting – 151
•
•
•
•
•
•
•
102 Figure - The "mint rf6.0 map detail" command output
Pay attention to the indicators in the "Options" column. The following values are possible:
M - Master device;
S -Slave device;
TM - Master device with software having support for the TDMA technology;
L - the throughput is limited by license;
F - the software version is older than the one on the local device.
A question mark in front of the remote's device name indicates that it has no password.
Pay attention to the "*" symbol, which can represent the following:
At the "pwr" column - hardware device failure.
At the "rssi" column -significant difference between the signal power of the vertical and horizontal
polarizations.
Radio statistics
Command line interface
To display statistics via the command line interface, use the ""rfconfig stat
50
" command.