Install Instructions

Table Of Contents
Infinet Wireless: Technical Documentation – InfiMAN Evolution
Operation & Administration – 135
81 Figure - Unit reboot
«Restore Factory Settings» - restores the factory default configuration. A warning message pops up, asking
for the permission before the operation to start. During the reset to factory process, you are redirected to the
login page and the timeout period of 30 seconds counts down before the new login:
«View Current License» - shows the current device license parameters in a new window
«View Current Configuration» - shows the current device configuration in text format in a new window
«Create Diagnostic Card» - Tech Support Reports Generator. By clicking this button, the system downloads
to the local PC a text file that contains the complete information (for the technical support specialists) set
from the device such as: full device configuration listing, system log output, license information, “mint map
detail” command output, interfaces statistics, etc.
7.5 Spectrum Analyzer menu
In the "Spectrum Analyzer" menu, you can perform a deep analysis of the radio emissions in the environment where
the unit is placed. The unit scans the radio spectrum on all available frequencies. In order to obtain the information
as accurate as possible, the scanning process may take a while.
82 Figure - Spectrum analyzer
The following parameters are available in order to operate the Spectrum Analyzer:
Parameter Description
Interface rf6.0 radio interface is the only option available, but it is showed for
the backward compatibility with the dual radio legacy products
Start Frequency Set the first frequency for scanning (in MHz)
Stop Frequency Set the last frequency for scanning (in MHz)
Band Set the bandwidth (in MHz)
CAUTION
When running spectrum scan on a unit accessible via the RF interface, connection will be lost during scan
time (the radio-link will be disconnected). Use "Last Snapshot" button to see scan results.