Manual
3 - 2
IPN 074-544-P1A
CI-100 Crucible Indexer Operating Manual
Select/Speed Display
Normally shows the desired pocket in Manual mode. Normally blank in Auto
mode.
If the indexer is sweeping in a continuous (i.e. banana) pocket, then the decimal
point flashes and the sweep speed is displayed.
CW/CCW Switch
This spring-loaded switch moves the indexer clockwise or counterclockwise.
Push and hold for continuous rotation. If Uni-Direction is selected on the rear
panel, only moves the indexer in one direction.
The Pocket/Jog switch controls the degree of movement that occurs when
CW/CCW is pushed.
Pocket/Jog Switch
Select Pocket to cause moves between pockets. Select Jog to cause moves in
1.8° increments. Use the CW/CCW switch to initiate the move.
Calibrate/Speed Switch
Press and hold to the Calibrate position for 3 seconds to electronically store the
selected pocket’s home position.
Press to the Speed position to start sweeping a continuous pocket. Press
Speed again to stop the sweep. Use the CW/CCW switch to adjust the sweep
speed. While sweeping, the Select/Speed display shows the selected speed:
Display Hi Speed (RPM) Lo Speed (RPM)
1 0.5 0.05
2 0.6 0.06
3 0.8 0.08
4 1.0 0.10
5 1.2 0.12
6 1.5 0.15
7 1.9 0.19
8 2.4 0.24
9 3.0 0.30
0 3.7 0.37
On discrete pockets, the Speed position has no effect.
Pocket Display
Shows the pocket that the indexer is on.