Instructions / Assembly
10
OPERATION
Flame Characteristic
The flame pattern at the emitter grid (spiral metal strip)
If you experience any ignition problem consult the following
“Troubleshooting”.
These lighting instructions must be followed. An unsafe
condition can occur if they are not followed correctly.
SAFETY FEATURE
In case of accidental break down of the flame due to wind or
other reasons, a Flame Safety Device (FSD) will
automatically shut-off gas supply within 90 seconds.
should be visually checked whenever heater is operated.
If black spot is accumulating on the emitter grid or reflector,
the heater should be turned off immediately. The heater
should not be operated again until the unit is serviced and
or repaired.
4Push in gas control knob and turn counter clockwise to
IGNITE " " then to PILOT " " position, this will light
the pilot. If needed, keep depressing and turning control
knob counter clockwise until the pilot lights. (You will
hear 1 clicking noise)
5. Once the pilot is lit, keep the control knob depressed for
approx. 30 seconds. Then release the control knob.
6. If pilot does not stay lit, repeat steps 4 and 5 after 5
minutes.
7. If pilot still does not stay lit, proceed as follows:
a) Push in gas control knob and turn counter clockwise
to the PILOT “ ” position.
b) Keep depressing the control knob, put a long stem
lighter into the ignition hole on the emitter screen
to light the pilot.
c) Repeat step 5.
8. Push in and turn control knob between LOW “ ” and
HIGH “ ” to get your desired warmth.