User's Manual

Technical Document
430695-01
Rev. F
Indyme Solutions, Inc. 8295 Aero Place San Diego, CA 92123 USA +1.858.268.0717 +1.800.829.6141 Page 1 of 6
CB942A Wireless Help Button
Programming and Installation Instructions
Introduction
The CB942A is a member of the Global Solutions Family. Indyme GSF
products operate in the 800MHz ʹ 900MHz frequency spectrum. The
CB942A is a 1-button, GSF help button designed for use at customer
service or sales floor locations. GSF Help Buttons are designed to
communicate with a GSF Access Point. GSF products are not compatible
with legacy devices.
Hardware
x (1) strip, double sided adhesive
x (1) package alcohol swap
Programming Parameters
GSF products MUST be properly programmed to establish communication. Programming parameters MUST
match your configuration. The default settings are for testing purposes only and should not be used. Failure
to properly program your help button and access point will prevent your devices from working.
GSF Help buttons have four primary programming parameters; Frequency Plan, Netcode, Address and
Operating Mode. These MUST be programmed in the correct order to establish communication and ensure
proper operation. Identify the parameters for your configuration before you begin programming.
Using the programming instructions below set the following parameters in order.
x Frequency Plan ʹ defines the frequency for your GSF devices.
x Netcode ʹ unique identification code for the installation environment.
x Address ʹ alarm number associated with a control unit alarm event.
x Operating Mode ʹ defines how the help button will respond when activated.
Programming a help button requires a series of button presses. The specific buttons vary by device type.
On the CB942A, ^dŝƐƚŚĞůĂƌŐĞďƵƚƚŽŶŝŶƚŚĞŵŝĚĚůĞand RESET is the small circle to the right The
assurance LED is red and is located Above to the SET button. This LED will flash during programming to
indicate your progress.
Frequency Plan *FP03 USA/Australia -918.100MHz
Netcode *00000001
Address *0001
Operating Mode *1
* Default parameters are for testing purposes only.
CB942A
RESET
LED