Install the Smart Sense Touch (DM9025)
The DM9025 is a device that monitors suspicious movement on a fixture. Based on the profile (sensitivity)
setting of the device, movement or vibrations will broadcast a message over the desired output device, alerting
associates of suspicious activity.
There are three ways to properly mount the DM9025. The installer can use a Christmas tree fasteners, 3M
adhesive (double-sided tape), or zip ties, all of which are included with each device.
3M adhesive
Use the Sterile Alcohol Prep Pad included with the device to clean the surface, making sure it is smooth and
clear of any small residue that can get on the tape. Attach both pieces of the 3M adhesive to the back plate.
After determining the best orientation for the device, attach it to the cleaned surface and make sure it is secure
and flush.
Removal
To remove the Touch Sensor, slowly pull the device from the surface by its backplate. This will ensure it
stays assembled. Use a flathead screwdriver to help separate the device from the surface as needed.