DT 200 Users Manual version 1.E    Built In Application Programs 
    12 
# 2 Checkweigh: Under/Between/Over 
The indicator monitors the scale for activity. When the scale goes above the ‘empty’ 
weight, the indicator waits for stable weight, and then outputs an indication of Under, 
Between (OK), or over. The cycle resets when the scale goes below the empty weight. 
Installation 
Connect TTL outputs to relay or lamp actuators. 
  Under weight indication    TTL 1    TB4 - Pin 1 
  Between weight indication  TTL 2    TB4 - Pin 2 
  Over weight indication    TTL 3    TB4 - Pin 3 
  Ground        GND    TB4 - Pin 16 
Configure ‘empty’ scale weight. (Parameter 43) 
Operators Functions 
Enter setpoint weights 
Press the F1 key. The display prompts “SP 1. Use the numeric keyboard to enter 
setpoint 1, then press the ENTER key. The display prompts “SP 2”. Use the numeric 
keyboard to enter setpoint 2, then press the ENTER key. NOTE: use the F2 key to enter 
a decimal point if needed. 
Recalculate 
Press the F2 key to re-check the weight on the scale. 