DT 200 Users Manual version 1.E    Built In Application Programs 
    11 
#1 Fill to Setpoint 
Press F1 key to enter a setpoint. Place an empty container on the scale. Press F2 key to 
begin filling. TTL output 1 turns on until the weight on the scale is equal or greater than 
the setpoint. 
Installation 
Connect TTL output 1 to relay or lamp actuator. 
  TB4 - Pin 1  TTL output 1 
  TB4 - Pin 16  Ground (GND) 
Setup Parameters: 
(See chapter 5: Set Operation Parameters for setup details) 
Parameter 43 Minimum scale weight to begin filling. Verifies that a container is on the 
scale. Set to 0 if there is no minimum. 
Parameter 44 Minimum fill amount. Set to some small value to insure that a fill amount 
has been entered. 
Parameter 45 Maximum fill amount. Maximum fill weight that will ever be used. 
Parameter 46 Scale empty weight. Maximum weight to begin fill. Verifies that an empty 
container is on the scale. 
Operators Functions 
Enter setpoint 
Press F1 key to enter the setpoint. Enter the setpoint weight, then press the ENTER key. 
Start fill operation 
Place the container on the scale (if required). Press F2 key to begin fill operation. 
Stop fill operations 
Press the Clear key to stop fill operation. 
Print Results 
Press the Print key to print the Gross, Tare, and Net results of the fill operation. 
Error Codes 
Error 30 = scale not empty 
Error 31 = minimum weight error: container is not on scale 
Error 32 = tare weight error: tare function failed, scale not stable (motion) 
Error 33 = setpoint less than minimum setpoint amount 
Error 34 = setpoint more than maximum setpoint amount 