User's Manual
7
Mode selection is accomplished using switches 1 thru 3. The following
configurations will give you the desired modes.
Switch numbers
Modes #1 #2 #3
Semi-Auto off off off
2 shot Burst on off off
3 shot Burst off on off
6 shot Burst on on off
Auto-Response off off on
Turbo Mode on off on
Zip (ramp) off on on
Full Auto on on on
Rate of Fire and timing is as follows:
Dip switch #4 and #5 (registers Solenoid on times in milliseconds)
#4 #5
off off = 06 ms (.006 seconds)
on off = 08 ms (.008 seconds)
off on = 10 ms (.010 seconds)
on on = 12 ms (.012 seconds)
Dip switch #6, #7 and #8 (registers Solenoid off (delay before re-cycle) times in
milliseconds)
#6 #7 #8
off off off = 70 ms (.070 seconds)
on off off = 80 ms (.080 seconds)
off on off = 90 ms (.090 seconds)
on on off = 100 ms (.100 seconds)
off off on = 110 ms (.110 seconds)
on off on = 120 ms (.120 seconds)
off on on = 130 ms (.130 seconds)
on on on = 140 ms (.140 seconds)
Calculating the cycles per second is easy and precise. For instance, if, S4 is off &
S5 is on, S6 & S7 are off and S8 is on the rate is calculated as .010 + .110 = .120.
The total cycle times for .120 = 8.33 cycles per second (1 divided by .120).
This is the calculation for Balls Per Second.