User manual
18Feedback
© 2012 Index Braille
5 Feedback
All local speech feedback languages available as of the day of shipment,s will be included in the
embosser. New speech feedback languages will gradually become available at Index Braille's
website free of charge. Upgrade to the latest speech interface by following the instructions at V4
Knowledge Base at www.indexbraille.com
The speech feedback uses the internal speaker as default. By inserting a standard headphone or
external speaker you will increase the speech quality and volume. The headphone connector is
located in the back of the embosser.
5.1 LED feedback
5.1.1 Front panel LED
The Green LED close to the Index logo indicates 48 Voltage input power.
Embosser
status
Green
48V
Yellow
Red
Idle
ON
ON
The embosser has completed the starting up
sequence and is ready to emboss
Embossing
ON
SLOW
Embossing in progress
Embossing and
printing
ON
FAST
For ATC Braille & Print
Menu active
ON
ON
Menu selection from front panel menu is active
Value active
ON
SLOW
ON
Insert values from front panel is active
Command
center active
ON
SLOW
Run the command center
Upgrade active
ON
SLOW
SLOW
Wait during the upgrade process, it takes up to 120
seconds and is completed when the embosser gives
the Ready speech message
Error minor
ON
FAST
Press ON LINE for coming to idle status
Error major
ON
FAST
FAST
Re-start the embosser to reset error position
5.1.2 Basic/Everest interface LED (back side)
Green
Yellow
Basic-D
Paper sensor located
on the green arrow
Paper movement indicator (not implemented in
firmware 1.3x)
Everest
Paper sensor located
above the embossing
head
not used