Operating Instructions HOB Contents GB English,1 Installation, 2-5 Positioning Electrical connection Gas connection Data plate Burner and nozzle specifications Electrical Connection, 6 Description of the appliance, 7 Overall view Start-up and use, 8 Practical advice on using the burners Precautions and tips, 9 SH06SGMAX SH07SGWAX General safety Disposal Maintenance and care, 10 Switching the appliance off Cleaning the appliance Gas tap maintenance Troubleshooting, 11 After sales support, 12 GB
Installation also be equipped with vents to allow gas to escape in the event of a leak. As a result LPG cylinders, whether partially or completely full, must not be installed or stored in rooms or storage areas that are below ground level (cellars, etc.). It is advisable to keep only the cylinder being used in the room, positioned so that it is not subject to heat produced by external sources (ovens, fireplaces, stoves, etc. ) which could raise the temperature of the cylinder above 50°C.
Back There is an adjustable L-shaped pipe fitting on the appliance supply ramp and this is fitted with a seal in order to prevent leaks. The seal must always be replaced after rotating the pipe fitting (seal provided with appliance). The gas supply pipe fitting is a threaded 1/2 gas cylindrical male attachment.
GB 3. replace all the components by repeating the steps in reverse order. Adjusting the burners primary air : Does not require adjusting. Setting the burners to minimum: 1. Turn the tap to the low flame position. 2. Remove the knob and adjust the adjustment screw, which is positioned in or next to the tap pin, until the flame is small but steady. 3.
Burner and nozzle specifications Table 1 Liquid gas Burner Diameter Thermal Thermal By-pass Nozzle (mm) power power 1/100 1/100 kW kW (mm) (p.c.s.*) (p.c.s.*) Red. Nom. GB Natural gas Flow* g/h Thermal Nozzler power 1/100 kW (p.c.s.*) (mm) *** ** Nom.
Electrical Connection GB Power supply voltage and frequency: 220-240V a.c. 50/60Hz. The supply cable must be positioned so that it never reaches at any point a temperature 50°C higher than the room temperature. The cable must be routed away from the rear vents. Should you require it, you may use a longer cable, however, you must ensure that the cable supplied with the appliance is replaced by one of the same specifications in accordance with current standards and legislation.
Description of the appliance Overall view GB GAS BURNERS Support Grid for COOKWARE Control Knobs for GAS BURNERS Support Grid for COOKWARE GAS BURNERS Control Knobs for GAS BURNERS SAFETY DEVICES * GAS BURNERS differ in size and power. Use the diameter of the cookware to choose the most appropriate burner to cook with. Control Knobs for GAS BURNERS adjust the power or the size of the flame. GAS BURNER ignition * enables a specific burner to be lit automatically.
Start-up and use GB The position of the corresponding gas burner or electric hotplate* is shown on every knob. Gas burners Each burner can be adjusted to one of the following settings using the corresponding control knob: Off Maximum Minimum To light one of the burners, hold a lit match or lighter near the burner and, at the same time, press down and turn the corresponding knob anti-clockwise to the maximum setting.
Precautions and tips This appliance has been designed and manufactured in compliance with international safety standards. The following warnings are provided for safety reasons and must be read carefully. General safety This is a class 3 built-in appliance. Gas appliances require regular air exchange to maintain efficient operation. When installing the hob, follow the instructions provided in the paragraph on Positioning the appliance.
Maintenance and care GB Switching the appliance off Disconnect your appliance from the electricity supply before carrying out any work on it. Cleaning the appliance Do not use abrasive or corrosive detergents such as stain removers, anti-rust products, powder detergents or sponges with abrasive surfaces: these may scratch the surface beyond repair. Never use steam cleaners or pressure cleaners on the appliance.
Troubleshooting It may happen that the appliance does not function properly or at all. Before calling the service centre for assistance, check if anything can be done. First, check to see that there are no interruptions in the gas and electrical supplies, and, in particular, that the gas valves for the mains are open. GB Problem Possible causes/Solution The burner does not light or the flame is not even around the burner. • The gas holes on the burner are clogged.
After sales support 04/2010 - 195082782.00 XEROX FABRIANO Scholtès UK | Morley Way, Peterborough, PE2 9JB t. 0800 158 55 00 e. info@scholtes.co.uk w. scholtes.co.uk GB Commitment to after sales support Thank you for investing in Scholtès Scholtès products are designed to perform consistently and reliably throughout their life. To give you further reassurance Scholtès ensures your appliance benefits from a five year guarantee.