Instruction for Use

8
AUS
* At 15°C and 1013,25 mbar - dry gas
** Propane G31 H.s = 50.37 MJ/Kg
*** Butane G30 H.s. = 49.47 MJ/Kg
Natural G 20 H.s. = 37.78 MJ/m
3
Rapid
Semi Rapid
Auxiliary
Inner DCDR
Outer DCDR
Total NHGC
(only for CP 059 MD AUS)
Burner Ø Injector
(mm)
GC (MJ/hr)
1.29
1.10
0.80
0.80
2 x 1.19
8.3
6.0
3.3
3.3
13.0
39.9
Ø Injector
(mm)
0.80
0.64
0.50
0.50
2 x 0.70
8.0
4.7
3.0
3.0
13.5
36.9
GC (MJ/hr)
Natural gas (1.0 kPa) ULPG (2.75 kPa)
Burner and nozzle specifications
Rapid
Semi Rapid
Auxiliary
Triple Ring
Total NHGC
(only for CP 859 MT AUS)
Burner Ø Injector
(mm)
GC (MJ/hr)
1.29
1.10
0.80
1.75
8.3
6.0
3.3
15.0
38.6
Ø Injector
(mm)
0.80
0.64
0.50
1.05
8.5
5.5
3.0
15.0
37.5
GC (MJ/hr)
Natural gas (1.0 kPa) ULPG (2.75 kPa)
Adjusting the hob burners’ minimum setting:
1. Turn the tap to the minimum position.
2. Remove the knob and adjust the regulatory screw, which is positioned
inside or next to the tap pin, until the ame is small but steady.
! If the appliance is connected to a liquid gas supply, the regulatory screw
must be fastened as tightly as possible.
3. While the burner is alight, quickly change the position of the knob from
minimum to maximum and vice versa several times, checking that the ame
is not extinguished.
Checking the operation
Ignite each burner and check the appearance of the ame, the ame should
be blue and burn smoothly on high & low.
Ensure complete igniton of all burners.
Where the data plate is obscured by cabinetry when the cooker is in the
installed position, place the supplied duplicate data plate to a suitable adjacent
surface or within this manual for future reference.
For other minor adjustments or if the appliance does not perfrom correctly;
contact Arisit Pty Ltd 1300 762 219.
! The hob burners do not require primary air adjustment.
! After adjusting the appliance so it may be used with a different type of
gas, replace the old rating label with a new one which corresponds to
the new type of gas (these labels are available from Authorised Technical
Assistance Centres).
! Should the gas pressure used be different (or vary slightly) from the
recommended pressure, a suitable pressure regulator must be tted to the
inlet hose in accordance with current national regulations relating to “regulators
for channelled gas”.