Owner's Manual

Golden Tee
®
Online Home Edition Version 10/17 Page 30
© Copyright 2017 Incredible Technologies, Inc. All Rights Reserved. Unauthorized duplication is a violation of applicable law.
All other marks are the properties of their respective owners. All rights reserved.
Flash Code Messages
Flash Code (I/O Diode
D102)
Code Description
Solution
Flash Code 2
Possible IO board failure
First Check Connections. Turn off game,
wait 10 seconds, turn game on. If
Problem persists call IT tech support.
Flash Code 3
Info: Last reboot due to Watchdog time
out.
Turn off game, wait 10 seconds, turn
game on. If Problem persists call IT tech
support.
Flash Code 4
Error When updating CID to latest
Version
Typically CID failure. Turn off game, wait
10 seconds, turn game on. If Problem
persists call IT tech support.
Flash Code 5
Updated USB CID was detected. This
is not an error but a notification.
Turn off game, wait 10 seconds, turn
game on. If Problem persists call IT tech
support.
Flash Code 6
Disconnected Cabinet ID Device (CID)
was detected.
Check USB connection. Turn off game,
wait 10 seconds, turn game on. If
Problem persists call IT tech support.
Flash Code 7
CID Malfunction. Typically CID is
defective.
Turn off game, wait 10 seconds, turn
game on. If Problem persists call IT tech
support.
Flash Code 10
Error When updating USB I/O board to
latest version. Typically an I/O board
failure
Turn off game, wait 10 seconds, turn
game on. If Problem persists call IT tech
support.
Flash Code 11
Updated USB I/O board to latest
version. This is not an error but a
notification.
Turn off game, wait 10 seconds, turn
game on. If Problem persists call IT tech
support.
Flash Code 12
A disconnected IO board was detected.
Turn off game, Check USB and power
connections, turn game on. If Problem
persists call IT tech support.
Flash Code 13
I/O board malfunction. Typically I/O
board has failed.
Turn off game, wait 10 seconds, turn
game on. If Problem persists call IT tech
support.
Flash Code 14
Game is incompatible with USB I/O
board.
This usually means the wrong type of I/O
board. It does not match the system box
software. Try turning off game, wait 10
seconds, turn game on. If problem
persists call IT tech support.
Miscellaneous Problems
Symptom
Probable Cause
Solution
Unable to exit Operator Menus.
DIPswitch SW202 position 4 is in
the on position.
Set position 4 of SW202 to off.
Press start to exit.
Test switch wired from the I/O
Board is closed.
Verify satellite test switch is not
closed.
No fluorescent light
No 120 volts A.C. power going to
the light fixture.
Verify A.C. voltage to the light
fixture.
Defective fluorescent light.
Replace fluorescent light.
Defective starter
Replace the starter.
Defective ballast.
Replace the ballast.