Operators Manual Instruction Manual

800-446-7488 19 www.in-situ.com
l Up to 16 messages (80 values) can be transmitted at one time.
8. Click the checkmark.
9. Repeat steps 5 - 8 for all other SMS messages.
10. Delete a message by selecting it and clicking Delete to remove it from the list.
11.
Click the Load Configuration button.
12. Click Test.
13. The TROLL Link Setup Software prompts you to disconnect. Click the Disconnect
button.
14. Wait for the message to be sent to your phone or email address.
SMS Data Appearance
Each SMS data message contains seven comma-separated values:
-----Original Message-----
From: 9716906987@tmomail.net [mailto:9716906987@tmomail.net]
Sent: Thursday, June 14, 2012 2:46 PM
To: youremail@youremailprovider.com
Subject:
Number Description
1 21:45Time the data were measured
2 2SMS message number (set in the Messages tab)
3
3.000, n, n, n, nParameter measurement values.
Numeric values equal actual measurements
•"n" equals no measurement taken
"e" equals an attempted measurement, but the device did not respond
4
b0c0r0TROLL Link system messages
"b" equals battery status, where 1 = battery ok, 0 = low battery (11 V or less)
"c" equals counter status, where 1 = counter on, 0 = counter off
"r" equals relay status, where 1 = relay on, 0 = relay off