Microstepping Drive User's Manual
Appendix C - Using Non-IDC Motors with the Impulse
C-4
Anti -Resonance
• Damping Gain 1 - Enter the recommended value.
• Damping Gain 2 - If a value is present you may leave it as
is or enter a value according to the table:
Note: Both Damping Gains (1 and 2) must be configured.
• Click OK and you will return to the Motor Editor.
• Click OK or Save in the Motor Editor window. You will be prompted to overwrite an exist-
ing file.
Damping Gain 2
Motor Frame Size Enter This Value
17 6.0
23 4.0
34 2.0