User Manual
 Card Setup 
Sealevel Systems COMM+4.PCI Page 6 
Clock Modes 
The COMM+4.PCI employs a unique clocking option that allows the end user 
to select from divide by 4, and divide by 1 clocking modes. These modes are 
selected at Header J1. 
To select the Baud rates commonly associated with COM: ports (i.e. 2400, 
4800, 9600, 19.2, … 115.2K bps) place the jumper in the divide by 4 mode 
(silk-screen D4). 
To select the Baud rates above 115.2K select the divide by 1 mode (silk-screen 
D1). 
Baud Rates and Divisors for the ‘DIV1’ mode 
The following table shows some common data rates and the rates you should 
choose to match them if using the adapter in the ‘DIV1’ mode. 
For this Data Rate  Choose this Data Rate 
1200 bps  300 bps 
2400 bps  600 bps 
4800 bps  1200 bps 
9600 bps  2400 bps 
19.2K bps  4800 bps 
57.6 K bps  14.4K bps 
115.2 K bps  28.8K bps 
230.4K bps  57.6 K bps 
460.8K bps  115.2 K bps 
If your communications package allows the use of Baud rate divisors, choose the 
appropriate divisor from the following table: 
For this Data Rate  Choose this Divisor 
1200 bps  384 
2400 bps  192 
4800 bps  96 
9600 bps  48 
19.2K bps  24 
38.4K bps  12 
57.6K bps  8 
115.2K bps  4 
230.4K bps  2 
460.8K bps  1 