ACB-MB+4.PCI User Manual 
Technical Description 
The ACB-MB+4.PCI utilizes the Zilog 85230 Enhanced Serial Communications 
Controller (ESCC) and includes a dedicated Z85230 per port. This chip features 
programmable baud rate, data format and interrupt control. Refer to the ESCC Users 
Manual, available from Zilog, for details on programming the 85230 ESCC chip. 
Internal Baud Rate Generator 
The baud rate of the ESCC is programmed under software control. The standard 
oscillator supplied with the board is 7.3728 MHz. However, other oscillator values 
can be substituted to achieve different baud rates. 
Control and Status Registers Definition 
The control and status registers occupy 12 consecutive I/O locations. The following 
tables provide a functional description of the bit positions. X = do not care. 
Base Mode D7 D6  D5  D4  D3 D2  D1  D0 
+4 
RD 0 IRQST  0  0  0  0  0  DSRA 
+5 
RD 485CLK ECHOA SYNCA_RTS SYNCA_CTS AM3  AM2  AM1 AM0 
+5 
WR 485CLK ECHOA SYNCA_RTS SYNCA_CTS  AM3  AM2  AM1  AM0 
+6 
RD 0  0  0  0  RLA LLA TSETSLA RXCOPTA 
+6 
WR X  X  X  X  RLA LLA TSETSLA RXCOPTA 
+7 
RD X  X  X  X  IRQST4 IRQST3 IRQST2 IRQST1 
+14 
RD SD7 SD6  SD5  SD4  SD3 SD2  SD1  SD0 
+15 
RD SD15 SD14  SD13  SD12  SD11 SD10  SD9  SD8 
Field Description 
IRQST 
SCC interrupt status: 
1 = No interrupt pending on ESCC 
0 = Interrupt pending on ESCC. 
DSRA 
DSRA: 
1 = DSRA not active 
0 = DSRA active 
LLA 
Local Loopback:  1 = LL set 
0 = LL not set 
RLA 
Remote Loopback:  1 = RL set 
0 = RL not set 
TSETSLA 
TSET clock source:  1= Received TXC as source 
0 = TRXCA as source 
RXCOPTA 
RXCOPTA:  1= Selects SCC PCLK for RTXCA 
0 = Selects received RXC for 
 RTXCA 
SYNCA_RTS 
SYNCA _RTS:  1 = SYNCA connected to RTS 
0 = SYNCA is high 
SYNCA_CTS 
SYNCA_CTS:  1 = SYNCA connected to CTS 
0 = SYNCA is high 
485CLK 
TSET switches with TXD:  1 = clk switches 
0 = no CLK switching 
ECHOA 
ECHO enable:  1 = echo disabled 
0 = echo enabled 
AM0 – AM3 
I/O mode select. See table for valid interface options. 
0 = High Impedance 
SD0 – SD15 
Optional security feature. Unique value per customer or application. 
Default value = FFFF 
Note: Default values are listed in bold 