Owner manual
  Technical Description 
Sealevel Systems ACB-MP.PCI Page 3 
25 Pin Connector Signal Layouts (DB-25 Male) 
RS-232 Signals 
Signal Name  Pin # Mode 
GND Ground  7   
RD Receive Data  3  Input 
CTS  Clear To Send  5  Input 
DSR  Data Set Ready  6  Input 
DCD  Data Carrier Detect  8  Input 
TXC Transmit Clock  15  Input 
RXC Receive Clock  17  Input 
RI Ring Indicator  22 Input 
TSET  Transmit Signal Element Timing  24  Output 
DTR  Data Terminal Ready  20  Output 
TD Transmit Data  2  Output 
RTS  Request To Send  4  Output 
RI- is
 connected to Port B CTS on the 85230 and the enable bit is set in Base+6. 
DSR- is connected to Port B DCD on the 85230 the enable bit is set in Base+6. 
Technical Note: Please terminate any control signals that are not going to be used. The most common way to do this 
is connect RTS to CTS and RI. Also, connect DCD to DTR and DSR. Terminating these pins, if not used, will help 
insure you get the best performance from your adapter. 










