Manual
© Sealevel Systems, Inc. 
- 6 - 
ACB-MP.PCI User Manual 
Interface Selection 
The ACB-MP.PCI supports a variety of electrical interfaces. Refer to the Control 
and Status Register Definitions found in the Technical Description section of this 
manual for this bit description. There is line termination on RXD, RXC, and TXC in 
the following modes: RS-530, RS-530A, RS-485T, and V.35. 
HEX M3 M2 M1 M0  Interface Mode 
0 0 0 0 0 
All signals are high impedance 
1  0  0  0  1  * not supported * 
2 0 0 1 0 
RS-232 
3  0  0  1  1  * not supported * 
4 0 1 0 0 
RS-485T with 120Ω termination 
5 0 1 0 1 
RS-485 without termination 
6,7,8,9  0  1  1  0  * not supported * 
A 1 0 1 0 
single ended loopback 
B 1 0 1 1 
differential loopback 
C  1  1  0  0  * not supported * 
D 1 1 0 1 
RS-530 
E 1 1 1 0 
V.35 
F 1 1 1 1 
RS-530A 
DB-25M Connector Pin Outs 
RS-232 Signals 
Base+5, M3-M0=2, 0010 
Pin #  Signal  Name  Mode 
2 TD Transmit Data  Output 
3 RD Receive Data  Input 
4 RTS Request To Send  Output 
5  CTS  Clear To Send  Input 
6  DSR  Data Set Ready  Input 
7 GND Ground   
8 DCD Data Carrier Detect  Input 
15 TXC Transmit Clock  Input 
17 RXC Receive Clock  Input 
18 LL Local Loopback  Output 
20  DTR  Data Terminal Ready  Output 
21 RL Remote Loopback  Output 
24  TSET  Transmit Signal Element Timing  Output 
25 TM Test Mode  Input 