Owner's manual
Table Of Contents
- Table of Contents
- Introduction
- SeaI/O Hardware Description
- SeaI/O Base and Expansion Modules
- SeaI/O Module Common Features
- SeaI/O Configurations & Specifications
- 410 Series – 16 Optically Isolated Inputs/16 Reed Relay Outputs
- 420 Series – 16 Optically Isolated Inputs/8 Form C Outputs
- 430 Series – 32 Optically Isolated Inputs
- 440 Series – 32 Reed Relay Outputs
- 450 Series – 16 Form C Relay Outputs
- 462 Series – 96 Channel TTL DB-78
- 463 Series – 96 Channel TTL 50-Pin
- 470 Series – 16 A/D, 2 D/A, 8 24V Outputs, 8 Isolated Inputs
- 520 Series – 8 Optically Isolated Inputs/8 High-Current Form C Outputs
- Power Options
- Hardware Configuration
- Wiring Options
- Mounting Options
- Accessories
- SeaMAX Application Suite
- SeaI/O Architecture
- Device Address Configuration
- Configuring the “Base” SeaI/O Module
- Configuring N-Series Expansion Modules
- Configuring an Ethernet Module (E-Series)
- MaxSSD Configuration & Diagnostics Utility
- Communicating Via Modbus
- Extended Modbus Command Set
- Developing Custom Applications Using SeaMAX API
- SeaMAX API
- Non Object-Oriented SeaMAX API
- IOCTL Calls and Functionality
- Using SeaMAX with Visual C++ 6.0
- Using SeaMAX with Visual Basic 6.0
- Example SeaMAX Programming Tasks
- CEthernet API
- Appendix A – Data Encoding Tables
- Appendix B – CRC Calculation
- Appendix C – SeaIO Model 462/463 Holding Register Set
- Appendix D – SeaMAX Data Types and Structures
- Appendix E – Troubleshooting
- Appendix F – How To Get Assistance
- Appendix G – Compliance Notices
- Warranty

© Sealevel Systems, Inc.
- 2 -
SeaI/O User Manual
Software Installation
SeaI/O modules can be used with industry standard Modbus protocol or easily
controlled from application programs using the supplied SeaMAX software libraries.
Included are two diagnostic and configuration tools: MaxSSD and Ethernet Config.
The SeaMAX library features an object-oriented and functional interface for use with
C++ and Visual Basic. Also included is the CEthernet API library for programmatic
discovery and configuration of Ethernet enabled SeaI/O modules. Refer to the
SeaMAX Application Suite section of this manual for detailed information.
Industry Segments
SeaI/O modules are perfect for a wide variety of applications and environments
including:
Process Control
Data Acquisition
Broadcast Automation
Security
Facility Management
Features
Choice of Connectivity:
o Wireless (802.11b/g) – coming soon!
o Ethernet
o USB
o RS-485
o RS-232
Supports Industry Standard Modbus TCP & RTU Protocols
Models Offering Choice of:
o Optically Isolated Inputs
o Reed Relay Outputs
o Form C Relay Outputs
o TTL Interfaces
o Analog A/D & D/A
Status Indicator LEDs for Communication, Fault, and Status
Field Removable Terminal Block Connectors (most models)
9-30VDC Power Input
Power Input via Terminal Block or DC Jack
Daisy Chain up to 247 Modules
Extended Temperature Available (-40°C to +85°C)
Rugged Metal Enclosure
Compact Size - 7.5"(L) x 5.1"(W) x 1.3"(H)
Din Rail or Table Mount