Instruction Manual
  Card Setup 
Sealevel Systems COMM+2/EX Page 3 
Port Enable / Disable 
Each port on the COMM+2/EX can be enabled or disabled with switch position 8 on the DIP-switch. The port is 
enabled with the switch ‘On’ or ‘Closed’ and disabled when ‘Off’ or ‘Open’. If any port is disabled, be sure to 
disable the interrupt request for that port by removing the IRQ jumper. 
Interface Selection 
RS-422/485 
To select the RS-422/485 mode of operation install dip shunts in sockets found at E6 and E7. E6 sets Port 1 and E7 
sets Port 2. 
RS-232 
To select the RS-232 mode of operation install dip shunts in sockets found at E5 and E8. E5 sets Port 1 and E8 sets 
Port 2. 
IRQ Selection 
Headers E1 and E2 select the interrupt request for each serial port (E1 - Port 2, E2 - Port 1). If COM1: is selected, 
the corresponding jumper must be on the IRQ4 setting. If COM2: is selected, the corresponding jumper must be on 
IRQ3. 
2/9 3 4 5 7 10 11 12 15
2/9 3 4 5 7 10 11 12 15
E2
E1
Figure 3 - Header E1 and E2, IRQ Selection 
Any two or more ports can share a common IRQ, provided a polling driver is used, by placing the jumpers on the 
same IRQ setting and setting the appropriate selections at E3. The following examples show the setup if a polling 
driver is used. NOTE: Windows does not provide a polling driver. Consult your particular software for IRQ 
selection. If no interrupt is desired, remove the jumper. 