User Manual
 Card Setup 
Sealevel Systems ULTRA-485 Page 2 
Card Setup 
The  ULTRA 485 contains several jumper straps that must be set for proper 
operation. 
Address Selection 
The ULTRA 485 occupies 8 consecutive I/O locations, and looks to the PC as a 
standard serial port. A DIP-switch (SW1) is used to set the port address options 
for the ULTRA 485. Be careful when selecting the port addresses as some 
selections may conflict with existing ports. The following table shows the 
addressing options available with the standard PAL. If different address options 
are required, please contact Sealevel Systems Technical Support about a custom 
PAL option. 
Port1 J2  SW1-1  SW1-2  SW1-3  SW1-4 
Disabled On  On  On  On 
3F8 On  On  On  Off 
2F8 On  On  Off  On 
3E8 On  On  Off  Off 
2E8 On  Off  On  On 
3220 On  Off  On  Off 
3228 On  Off  Off  On 
4220 On  Off  Off  Off 
4228 Off  On  On  On 
238 Off  On  On  Off 
300 Off  On  Off  On 
308 Off  On  Off  Off 
280 Off  Off  On  On 
288 Off  Off  On  Off 
290 Off  Off  Off  On 
298 Off  Off  Off  Off 
Note:  Each COM port in the system should have a unique address. Typically 
COM1: - COM4: addresses are 3F8, 2F8, 3E8 & 2E8 Hex. 