Installation
Powered Liners Installation Detail Continued: 
Figure 1: 
Figure one shows the included elbow 
transition from 7” diameter round to 3 
1/4” x 10” rectangular. This transition is 
used to return the filtered air back to 
inside the kitchen either through the 
canopy face of if applicable the soffit 
above. The customer must provide 
the appropriate length of straight 
7” round ducting that connects the 
hood exhaust to the elbow 
transition. 
Figure 2 
Figure two shows a typical air exit 
terminating through the canopy face. A 
customer supplied, decorative 4” x 10” 
register cover face plate should be 
used to finish off the cut out opening. 
Figure 3 
Figure three shows a typical air exit 
terminating through the soffit face 
directly above the hood canopy. 
Again the customer must provide a 
4” x 10” register face plate. 
Re-Circulating, (Non-Vented) Series: C2000SD2-NV 
For use when unable to terminate exhaust ducting to outside the structure. 
NOTE: The C2000 NV Unit comes supplied with charcoal filters that will accumulate 
the cooking grease and over time decrease the hoods performance. The amount and 
style of cooking will dictate how often the filters should be replaced. This type of filter 
is designed for replacement only. Contact Imperial to purchase proper replacement 
filters. 
View from rear of the canopy. 
Canopy Exit 
Soffit Exit 
Included 
Not Included 
Figure 1 
Figure 2 
4” x 10” Cover 
Face Plate 
4” x 10” Cover 
Face Plate 