WATER DRAINAGE
Certain functions of your air conditioning unit create condensation and the unit may need
to evacuate accumulated water. Please carefully follow these instructions according to your
operating and usage conditions.
COOLING MODE
During cooling mode, the unit attempts to evacuate all of the moisture through the exhaust
hose to the outside along with the warm air exhaust. At times, when the humidity level is very
high, excess water may collect in the bottom tray. If the water level of the bottom tray reaches
a predetermined level, the unit beeps 8 times, the digital display area shows error P1 . At this
time the air conditioning/dehumidification process will immediately stop, even though the fan
motor may continue running (this is normal).
Carefully move the unit to a drain location, remove the bottom drain plug and let the water
drain away (see Figure E). Reinstall the bottom drain plug and restart the machine until the P1
symbol disappears. If the error repeats, call for service.
NOTE: Be sure to reinstall the bottom drain plug before using the unit.
DEHUMIDIFYING MODE ONLY
Remove the upper drain plug from the back of the
unit and simply attach the drain hose to the hole.
Place the open end of the hose adapter directly over
the drain area in your floor or into another receptacle
(see Figure F).
NOTE: Make sure the hose is secure so there are no
leaks. Direct the hose toward a drain that is located
lower than the unit, making sure that there are no kinks that will stop water flow. Place the end of the hose into
the drain and make sure the end of the hose is down to let the water flow smoothly (see Figure F). Do not li up
the hose as this may cause water to flow back into the unit.
WINDOW SLIDER KIT INSTALLATION
Your window slider kit has been designed to fit most standard double-hung and slider windows, However, it may
be necessary for you to improvise/modify some aspects of the installation procedures for certain types of win-
dows. Please refer to Figure G & Figure H for minimum and maximum window openings. The window slider kit
can be fixed with an included security peg (see Figure I).
Window filler panel
Minimum: 2’ 1/8” (67.5cm)
Maximum: 4’ (123cm)
Fig. G
Standard
Double-hung
Window
Horizontal
Slider
Window
Fig. H
Window filler panel
Minimum: 2’ 2⅝” (67.5cm)
Maximum: 4’ (123cm)
Remove
drain plug
Continuous drain hose
Fig. I
Window
filler panel
Security Peg
Bottom drain
plug
Fig. E
Fig. F