User's Manual

13
Page 4 Page 13
Specications
1
Assuming ISO 100 Sensitivity. Guide numbers are shown as a starting point.
You should perform your own evaluations to determine the results you prefer.
A
B
C
D
E
F
G
H I
J
K
L
M
N
O
10M 25M 50M 75 M 100M 10Y 25M 50M 75M 100M
VS-LCD400
Power Output 400W
Guide Number
(ft/m)
1
205/63
Aperture 32
Recycling Time 3-4 seconds
Power Adjustment 1/16th to full power in .10 f/stop increments
Modeling Lamp 150W
Color Temperature 5700 ±200° K
Flash Triggers Sync cord, photo cell sensor, test button
Trigger Voltage 4.3V DC
Sync Range up to 40ft (12m)
Working Voltage 110-120V AC
User Replaceable Elements Modeling lamp, ash tube
Reector/Softbox Mount Fits Bowen style
Dimensions (with reector) 16˝ × 6˝ × 11.25˝ (410 × 155 × 285 mm)
Weight (approx.) 6.17 lb. (2.8 kg)
Error codes for VS-LCD400
In the event that one of the following error codes are displayed in the LCD screen, turn off
the unit and return it to the place of purchase for repair or exchange.
E1 means the input power is unstable.
E2 means the unit is overcharged.
E3 means the unit can’t be charged.