Operating instructions
GB
Problem Possible cause Solution
The plate remains
cold or does not
heat up.
There is no power supply.
Verify whether the plug is inserted
correctly or try inserting it in another
socket.
Verify whether the temperature
adjustment knob (2) is set to the
minimum temperature Ø (Fig D).
The plate
temperature LED
#$%&"$'"(')"$*+"
Normal procedure.
This indicates the heating phase of the
,-$'+"./%"012"#$%&"$*"$'3%"4/%"&%4"
temperature is reached.
Only a little steam
or none at all is
dispensed.
The steam selector (5) is
set to Ø .
Set the steam selector (5) to the
)%&,-%)"5%6)"78,#+"9:+
There is not enough water
in the reservoir.
Fill the reservoir.
The anti-drip system is
activated (if present).
Wait for the plate to reach the correct
temperature once again.
The impurities that
come out from the
steam holes stain
the garments.
Possible residue in the
steam chamber/plate.
Carry out the Self Clean procedure
(see paragraph Seal Clean/Calc-Clean
System).
Chemical additives,
scented liquids or
descaling agents are being
used.
These damage the product: do not add
additives to the water in the reservoir.
Pure distilled water or
softened water is being
used.
Mix tap water (50%) with distilled and
or demineralised (50%) water.
Starch is being used.
Always spray the starch on the reverse
side of the fabric.
Water escapes
from the plate.
The plate temperature
is too cold due to the
Super-steam button being
pressed too often (4).
Allow slightly longer intervals between
the jets of steam.
The temperature
adjustment knob (2) is set
to minimum Ø (Fig D).
Turn the temperature adjustment knob
(2) to a higher setting.
19